15562228838(微信同号)13963221227(微信同号)
2m*1/8 HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃
您所在的位置:首页 > 产品展示 > 填充柱

2m*1/8 HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃

如果你感兴趣的话,可以电话:0632-5667636

产品名称:2m*1/8 HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃

产品型号:2m*1/8

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,消毒剂,氨水,氨气,变压器油溶解气

2m*1/8 HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃的详细介绍

HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃
HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃 详细信息:

名称:总烃柱 总烃测定柱,材质为不锈钢或硬质玻璃, 长 2 m,内径 4 mm,内填充 60~80 目硅烷化玻璃微珠,或其他等效填充柱

2m*1/8

应用:HJ2017环境空气/固定污染源废气中甲烷,总烃,非甲烷总烃的测定

适用于:安捷伦,赛默飞,瓦里安,布鲁克,PE


为掌握实验室检测非甲烷总烃的技术能力,2021年,浩瀚色谱(山东)应用技术开发有限公司参加国家环境监测总站环境空气中非甲烷总烃能力考核,考核样按照《环境空气 总烃、甲烷和非甲烷总烃的测定 直接进样-气相色谱法》(HJ 604—2017)测定,能力考核结果满意。结果表明,采用直接进样-气相色谱法配双阀双柱双氢火焰离子化检测器,能同时测定环境空气中总烃、甲烷和非甲烷总烃,测定结果准确度高,精密度和重复性好,分析时间短,总烃、甲烷的校准曲线相关系数均大于0.999,该方法适用于环境空气中非甲烷总烃的日常检测。

HH-NMHC-2硅烷化玻璃微球测定环境空气中非甲烷总烃  测试谱图:




Determination of non-methane total hydrocarbons in ambient air by HH-NMHC-2 silanized glass microspheres
Determination of non-methane total hydrocarbons in ambient air by HH-NMHC-2 silanized glass microspheres Details:

Name: total hydrocarbon column Total hydrocarbon determination column, made of stainless steel or hard glass, 2 m long, 4 mm inner diameter, filled with 60-80 mesh silanized glass beads, or other equivalent packed columns.

2m*1/8

Application: Determination of methane, total hydrocarbons and non-methane total hydrocarbons in HJ2017 ambient air/stationary pollution source waste gas

Applies to: Agilent, Thermo Fisher, Varian, Bruker, PE


In order to master the technical ability of laboratory detection of non-methane total hydrocarbons, in 2021, Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. will participate in the assessment of non-methane total hydrocarbons in ambient air of the National Environmental Monitoring Station. Determination of Methane and Non-Methane Total Hydrocarbons by Direct Injection-Gas Chromatography" (HJ 604-2017), the ability assessment results are satisfactory. The results show that the direct injection-gas chromatography with double-valve double-column double-hydrogen flame ionization detector can simultaneously measure total hydrocarbons, methane and non-methane total hydrocarbons in ambient air with high accuracy, precision and repeatability. It has good performance, short analysis time, and the correlation coefficients of the calibration curves of total hydrocarbons and methane are all greater than 0.999. This method is suitable for the daily detection of non-methane total hydrocarbons in ambient air.

Determination of non-methane total hydrocarbons in ambient air by HH-NMHC-2 silanized glass microspheres Test spectrum:

相关产品

2m*4mm,, 挥发性有机物非甲烷总烃分布测定GDX-502柱
挥发性有机物非甲烷总烃分布测定GDX-502柱,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
1/16*35CM,, 4Å微径柱应用在PE580
4Å微径柱应用在PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
HH-H2HE-II,, 煤层中氢气和氦气的测定填充柱应用赛默飞130
煤层中氢气和氦气的测定填充柱应用赛默飞1300,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
30m*0.32mm*0.25um,, HH-FFAP毛细管色谱柱测定脂肪酸应用
HH-FFAP毛细管色谱柱测定脂肪酸应用岛津2010,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
2m*3mm;; 间苯二甲酸/GDX-103应用岛津2014测甲酸
间苯二甲酸/GDX-103应用岛津2014测甲酸,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
6m*3mm;; GDX-105填充柱应用于岛津赛默飞安捷伦
GDX-105填充柱应用于岛津赛默飞安捷伦,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 1+4等于多少?答案:5
 
仪器交易网
8
推荐收藏该企业网站