15562228838(微信同号)13963221227(微信同号)
聚乙二醇-20M 空气中环氧氯丙烷的新测定毛细管柱
您所在的位置:首页 > 产品展示 > 填充柱

聚乙二醇-20M 空气中环氧氯丙烷的新测定毛细管柱

如果你感兴趣的话,可以电话:0632-5667636

产品名称:聚乙二醇-20M 空气中环氧氯丙烷的新测定毛细管柱

产品型号:聚乙二醇-20M

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

空气中环氧氯丙烷的新测定毛细管柱,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,过氧化物,乙酸乙酯,顶空

聚乙二醇-20M 空气中环氧氯丙烷的新测定毛细管柱的详细介绍

空气中环氧氯丙烷的新测定毛细管柱
空气中环氧氯丙烷的新测定毛细管柱 详细信息:

名称:毛细管柱

固定液:聚乙二醇-20M

规格:30m*0.32mm*0.25um

型号:PEG-20M
应用:  空气中环氧氯丙烷的新测定

浩瀚色谱(山东)应用技术开发有限公司建立一种测定空气中环氧氯丙烷的新方法。方法:空气中的环氧氯丙烷用活性碳管采集,热解吸后,经PEG-20M柱分离,氢焰离子化检测器检测,对色谱柱,色谱条件,采集条件,热解吸条件等进行优选。结果:方法的检测限为0.001μg/m l,低检出浓度为0.03 mg/m3(采样体积3 L)。当标准溶液浓度为0.002、0.004、0.010μg/m l时,平均相对标准偏差为5.0%、4.8%、1.2%,标准曲线的相关系数为0.9999。平均解吸效率为97.1%,采样效率为95%,穿透容量大于1.4 mg。样品在采样管中可稳定7 d以上。结论:通过样品测试证明,该法采用活性碳管采样,携带方便,采样代表性好,样品稳定时间长;采样后解吸效率高;所选用的色谱柱具有柱效高,分离度好,色谱峰形好的优点。本法适用于现场监测和个体采样。


空气中环氧氯丙烷的新测定毛细管柱  测试谱图:



A new capillary column for the determination of epichlorohydrin in air
New capillary column for the determination of epichlorohydrin in air Details:

Name: capillary column

Fixative: polyethylene glycol-20M

Specifications: 30m*0.32mm*0.25um

Model: PEG-20M
Application: New determination of epichlorohydrin in air

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a new method for the determination of epichlorohydrin in air. Methods: The epichlorohydrin in the air was collected by activated carbon tube, and after thermal desorption, it was separated by PEG-20M column and detected by hydrogen flame ionization detector. Make optimization. Results: The detection limit of the method was 0.001 μg/m l, and the minimum detection concentration was 0.03 mg/m3 (sampling volume was 3 L). When the concentration of the standard solution was 0.002, 0.004 and 0.010 μg/ml, the average relative standard deviations were 5.0%, 4.8% and 1.2%, and the correlation coefficient of the standard curve was 0.9999. The average desorption efficiency was 97.1%, the sampling efficiency was 95%, and the penetration capacity was greater than 1.4 mg. The sample can be stable for more than 7 days in the sampling tube. Conclusion: It is proved by sample test that the method adopts activated carbon tube for sampling, which is convenient to carry, has good sampling representative, and has a long sample stability time; the desorption efficiency after sampling is high; the selected chromatographic column has high column efficiency, good resolution, and chromatographic peak good form. This law applies to on-site monitoring and individual sampling.


Test chromatogram of a new capillary column for the determination of epichlorohydrin in air:

相关产品

2m*4mm,, 挥发性有机物非甲烷总烃分布测定GDX-502柱
挥发性有机物非甲烷总烃分布测定GDX-502柱,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
1/16*35CM,, 4Å微径柱应用在PE580
4Å微径柱应用在PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
HH-H2HE-II,, 煤层中氢气和氦气的测定填充柱应用赛默飞130
煤层中氢气和氦气的测定填充柱应用赛默飞1300,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
30m*0.32mm*0.25um,, HH-FFAP毛细管色谱柱测定脂肪酸应用
HH-FFAP毛细管色谱柱测定脂肪酸应用岛津2010,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
2m*3mm;; 间苯二甲酸/GDX-103应用岛津2014测甲酸
间苯二甲酸/GDX-103应用岛津2014测甲酸,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
6m*3mm;; GDX-105填充柱应用于岛津赛默飞安捷伦
GDX-105填充柱应用于岛津赛默飞安捷伦,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 7+4等于多少?答案:11
 
仪器交易网
8
推荐收藏该企业网站