15562228838(微信同号)13963221227(微信同号)
HH-INNOWAX毛细管柱 进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定
您所在的位置:首页 > 产品展示 > 填充柱

HH-INNOWAX毛细管柱 进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定

如果你感兴趣的话,可以电话:0632-5667636

产品名称:HH-INNOWAX毛细管柱 进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定

产品型号:HH-INNOWAX毛细管柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定,乙酸乙酯,医疗器械,环氧乙烷,消毒剂,增塑剂,塑化剂,乙酸乙酯,医疗器械,氨水,氨气,炼厂气,甲缩醛,乙缩醛,过氧化物

HH-INNOWAX毛细管柱 进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定的详细介绍

进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定
进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定 详细信息:


名称:毛细管柱

固定相:聚乙二醇

规格:30m*0.32mm*0.5um

型号:HH-INNOWAX

应用:进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定 顶空-气相色谱法
本标准规定了进口环氧树脂涂料中环氧丙烷及环氧氯丙烷单体含量的顶空-气相色谱检测方法。 本标准适用于环氧树脂涂料中环氧丙烷及环氧氯丙烷单体的测定。


浩瀚色谱(山东)应用技术开发有限公司建立了顶空-气相色谱法测定环氧树脂涂料中环氧氯丙烷单体残留量的方法。结果表明,环氧氯丙烷含量在2.5~500μg范围内,线性方程为y=0.207 7x+0.348 2,相关系数为r=0.999 5;方法检出限为5 mg/kg;平均回收率为91.0%~98.1%;相对标准偏差(n=6)为1.3%~3.0%。该方法简便、快速,重复性好,可用于环氧树脂涂料中残留环氧氯丙烷单体的快速分析。





Determination of propylene oxide and epichlorohydrin monomers in imported epoxy resin coatings
Determination of propylene oxide and epichlorohydrin monomers in imported epoxy resin coatings Detailed information:


Name: capillary column

Stationary Phase: Polyethylene Glycol

Specifications: 30m*0.32mm*0.5um

Model: HH-INNOWAX

Application: Determination of propylene oxide and epichlorohydrin monomers in imported epoxy resin coatings by headspace-gas chromatography
This standard specifies the headspace-gas chromatography detection method for the monomer content of propylene oxide and epichlorohydrin in imported epoxy resin coatings. This standard applies to the determination of propylene oxide and epichlorohydrin monomers in epoxy resin coatings.


Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has established a headspace-gas chromatography method for the determination of residual epichlorohydrin in epoxy resin coatings. The results show that the content of epichlorohydrin is in the range of 2.5~500μg, the linear equation is y=0.207 7x+0.348 2, the correlation coefficient is r=0.999 5; the detection limit of the method is 5 mg/kg; the average recovery rate is 91.0% ~98.1%; relative standard deviation (n=6) was 1.3%~3.0%. The method is simple, rapid and reproducible, and can be used for the rapid analysis of residual epichlorohydrin monomers in epoxy resin coatings.

相关产品

2m*4mm,, 挥发性有机物非甲烷总烃分布测定GDX-502柱
挥发性有机物非甲烷总烃分布测定GDX-502柱,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
1/16*35CM,, 4Å微径柱应用在PE580
4Å微径柱应用在PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
HH-H2HE-II,, 煤层中氢气和氦气的测定填充柱应用赛默飞130
煤层中氢气和氦气的测定填充柱应用赛默飞1300,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
30m*0.32mm*0.25um,, HH-FFAP毛细管色谱柱测定脂肪酸应用
HH-FFAP毛细管色谱柱测定脂肪酸应用岛津2010,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
2m*3mm;; 间苯二甲酸/GDX-103应用岛津2014测甲酸
间苯二甲酸/GDX-103应用岛津2014测甲酸,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
6m*3mm;; GDX-105填充柱应用于岛津赛默飞安捷伦
GDX-105填充柱应用于岛津赛默飞安捷伦,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 7+8等于多少?答案:15
 
仪器交易网
8
推荐收藏该企业网站