15562228838(微信同号)13963221227(微信同号)
5%Carbowax 20M Carbopack B填充柱 气相色谱法测定大气废气中甲醇方法改进
您所在的位置:首页 > 产品展示 > 填充柱

5%Carbowax 20M Carbopack B填充柱 气相色谱法测定大气废气中甲醇方法改进

如果你感兴趣的话,可以电话:0632-5667636

产品名称:5%Carbowax 20M Carbopack B填充柱 气相色谱法测定大气废气中甲醇方法改进

产品型号:5%Carbowax 20M Carbopack B填充柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

气相色谱法测定大气废气中甲醇方法改进,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,过氧化物

5%Carbowax 20M Carbopack B填充柱 气相色谱法测定大气废气中甲醇方法改进的详细介绍

气相色谱法测定大气废气中甲醇方法改进
气相色谱法测定大气废气中甲醇方法改进 详细信息:

名称:填充柱

色谱固定液:5%聚乙二醇
载体:石墨炭黑80-120目

规格:2m*3mm,2m*1/8

型号:5%Carbowax 20M Carbopack B

应用: HJ T33-1999 固定污染源排气中甲醇的测定气相色谱法 

目前测定空气中甲醇的方法主要有品红亚硫酸比色法和气相色谱法.比色法的灵敏度25μg/5ml,不能满足环境中甲醇测定的需要.气相色谱法用纯水吸收空气中的甲醇,从该法的谱图可以看出与乙醇的分离不够理想,当空气中有大量的乙醇与甲醇共存时,对甲醇的分离将带来不利的影响.如要改善分离度,需加长柱子,但水的出峰时间将长达16分钟以上,大大加长了一个样品的分析周期.

浩瀚色谱(山东)应用技术开发有限公司采用5%Carbowax 20M Carbopack B填充柱,外标法定量,结果准确。

气相色谱法测定大气废气中甲醇方法改进  测试谱图:




Improvement of Gas Chromatography Method for Determination of Methanol in Atmospheric Waste Gas
Improved method for determination of methanol in atmospheric exhaust gas by gas chromatography. Details:

Name: Packed column
Chromatographic stationary liquid: 5% polyethylene glycol
Carrier: Graphite carbon black 80-120 mesh

Specification: 2m*3mm, 2m*1/8

Model: 5% Carbowax 20M Carbopack B

Application: HJ T33-1999 Determination of Methanol in Exhaust from Stationary Pollution Sources Gas Chromatography

The current methods for determining methanol in the air mainly include fuchsin sulfurous acid colorimetry and gas chromatography. The sensitivity of the colorimetric method is 25μg/5ml, which cannot meet the needs of methanol determination in the environment. Gas chromatography uses pure water to absorb methanol in the air. , It can be seen from the spectrum of this method that the separation with ethanol is not ideal. When a large amount of ethanol and methanol coexist in the air, it will have an adverse effect on the separation of methanol. If you want to improve the resolution, you need to lengthen the column. However, the peak time of water will be as long as 16 minutes, which greatly lengthens the analysis period of a sample.

Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. adopts 5% Carbowax 20M Carbopack B packed column, quantified by external standard method, and the results are accurate and reliable.

Improved method for determination of methanol in atmospheric exhaust gas by gas chromatography Test spectrum: 


相关产品

2.1m*3mm,, 10%SE-30/ Chromosorb G 填充柱应用PE580
10%SE-30/ Chromosorb G 填充柱应用PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
3m*3mm,, 三氟乙胺的分析专用填充柱应用PE580
三氟乙胺的分析专用填充柱应用PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
5%Carbowax20M Carbopack B,, HJ/T 33-1999安捷伦填充柱
HJ/T 33-1999安捷伦填充柱测定废气中的甲醇 ,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
0.5m*1/8,, Tenax-TA填充柱应用赛默飞1300
Tenax-TA填充柱应用赛默飞1300,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
Tenax-TA 石墨化碳黑+碳分子筛 +三氧化二铝:吸附采样管
石墨化碳黑+碳分子筛 +三氧化二铝:吸附采样管,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
HH-TXCH4 耐水的甲烷填充柱应用PE580测定固定污染源废气中CH
耐水的甲烷填充柱应用PE580测定固定污染源废气中CH4,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 1+0等于多少?答案:1
 
仪器交易网
8
推荐收藏该企业网站