15562228838(微信同号)13963221227(微信同号)
2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2
您所在的位置:首页 > 产品展示 > 填充柱

2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2

如果你感兴趣的话,可以电话:0632-5667636

产品名称:2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2

产品型号:2%OV-17/Chromosorb W填充柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

工作场所空气有毒物质测定硫化物CS2,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,医疗器械

2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2的详细介绍

工作场所空气有毒物质测定硫化物CS2
工作场所空气有毒物质测定硫化物CS2 详细信息:

名称:填充柱
规格:1.5m*4mm
型号:2%OV-17/Chromosorb W 60-80目
应用:GBZ/T 160.33-2004工作场所空气有毒物质测定 硫化物

为探讨我国粘胶作业工人的实际二硫化碳 (CS2 )接触水平以及现有的监测方法的代表性 ,浩瀚色谱(山东)应用技术开发有限公司应用国际上统一的采样分析方法对某粘胶长丝车间进行了车间空气中 CS2 浓度和 CS2 作业工人接触水平进行了测定 ,并对测定作业场所的 3种监测方法的代表性进行了评价.结果发现 ,用采样泵活性碳吸收管采样并以气相色谱分析法检测车间固定点 CS2 浓度为 :2 3.2 9± 1.35 m g/ m3,多功能气体分析仪测定结果为 12 .73m g/ m3,用个体采样法测得工人的实际接触水平为 :2 0 .0 5 mg/ m3.因而认为 :不宜以常用的车间内空气浓度来替代工人实际接触水平 ,因两者差异有统计学意义 (P<0 .0 1) ;建议工人实际接触水平应为个体采样法所测的结果或应以时间加权平均浓度表示为宜.

工作场所空气有毒物质测定硫化物CS2  测试谱图:



Determination of Toxic Substances in Workplace Air Sulfide CS2
Determination of Toxic Substances in Workplace Air Sulfide CS2 Details:

Name: Packed column
Specification: 1.5m*4mm
Model: 2%OV-17/Chromosorb W 60-80 mesh
Application: GBZ/T 160.33-2004 Determination of Toxic Substances in Workplace Air Sulfide

In order to explore the actual carbon disulfide (CS2) exposure level of Chinese viscose workers and the representativeness of existing monitoring methods, Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. applied an internationally unified sampling and analysis method to a viscose filament workshop The concentration of CS2 in the air in the workshop and the exposure level of CS2 workers were measured, and the representativeness of the three monitoring methods for measuring the workplace was evaluated. As a result, it was found that the sampling pump activated carbon absorber tube was used for sampling and analyzed by gas chromatography The concentration of CS2 at a fixed point in the workshop detected by the method is: 2 3.2 9± 1.35 mg/m3, the measurement result of the multi-function gas analyzer is 12.73 mg/m3, and the actual exposure level of the worker measured by the individual sampling method is: 20.0 5 mg/m3. Therefore, it is believed that it is not appropriate to replace the actual exposure level of workers with the commonly used air concentration in the workshop, because the difference between the two is statistically significant (P<0.01); it is recommended that the actual exposure level of workers should be the individual sampling method The measured result may be expressed as a time-weighted average concentration.

Test spectrum of sulfide CS2 for the determination of toxic substances in the workplace air: 


相关产品

2.1m*3mm,, 10%SE-30/ Chromosorb G 填充柱应用PE580
10%SE-30/ Chromosorb G 填充柱应用PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
3m*3mm,, 三氟乙胺的分析专用填充柱应用PE580
三氟乙胺的分析专用填充柱应用PE580,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
5%Carbowax20M Carbopack B,, HJ/T 33-1999安捷伦填充柱
HJ/T 33-1999安捷伦填充柱测定废气中的甲醇 ,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
0.5m*1/8,, Tenax-TA填充柱应用赛默飞1300
Tenax-TA填充柱应用赛默飞1300,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
Tenax-TA 石墨化碳黑+碳分子筛 +三氧化二铝:吸附采样管
石墨化碳黑+碳分子筛 +三氧化二铝:吸附采样管,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺
HH-TXCH4 耐水的甲烷填充柱应用PE580测定固定污染源废气中CH
耐水的甲烷填充柱应用PE580测定固定污染源废气中CH4,室内空气,非甲烷总烃,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,植物油,6号溶剂残留,变压器油溶解气,医疗器械,三甲胺

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 3-7等于多少?答案:-4
 
仪器交易网
8
推荐收藏该企业网站