丙烯中CO/CO2测TDX-01填充柱
简单介绍
丙烯中CO/CO2测TDX-01填充柱,液化石油气,焦炉煤气,炼厂气,粗苯,环氧乙烷,医疗器械,室内空气,变压器油,多氯联苯,脂肪酸,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气
丙烯中CO/CO2测TDX-01填充柱的详细介绍
丙烯中CO/CO2测TDX-01填充柱
丙烯中CO/CO2测TDX-01填充柱 详细信息:
滕州市浩瀚色谱仪器技术服务有限公司,气相色谱仪配置两个氢火焰检定器、一个甲烷转化炉一次进样同时测定出丙烯中CO、CO2及烃类杂质,建立了一种简单、准确、快速测定丙烯中微量杂质的分析方法。该方法相对标准偏差小于10%,检测线(S/N=3)为1mg/l,平均回收率94.3%~101.1%,分析速度快、稳定性好、效率高、结果准确。经过试验该方法完全能满足丙烯中CO、CO2及烃类杂质的分析。
丙烯中CO/CO2测TDX-01填充柱 测试谱图:



Hydride CO/CO2 measurement TDX-01 packed column
Hydride CO/CO2 measurement TDX-01 packed column Details:
Statio nary phase: carbon molecular sieve
Specification: 2m*3mm
Particle size: 60-80 mesh
Model: TDX-01
Material: Stainless steel
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd., gas chromatograph equipped with two hydrogen flame detectors, a methane reformer to simultaneously determine the CO, CO2 and hydrocarbon impurities in propylene, established a simple, accurate and fast Analytical method for the determination of trace impurities in propylene. The relative standard deviation of the method is less than 10%, the detection line (S/N=3) is 1mg/l, and the average recovery rate is 94.3%~101.1%. The analysis speed is fast, the stability is good, the efficiency is high, and the result is accurate and reliable. After testing, the method can fully meet the analysis of CO, CO2 and hydrocarbon impurities in propylene.
丙烯中CO/CO2测TDX-01填充柱 详细信息:
固定相:碳分子筛
规格:2m*3mm
粒度:60-80目
型号:TDX-01
材质:不锈钢
滕州市浩瀚色谱仪器技术服务有限公司,气相色谱仪配置两个氢火焰检定器、一个甲烷转化炉一次进样同时测定出丙烯中CO、CO2及烃类杂质,建立了一种简单、准确、快速测定丙烯中微量杂质的分析方法。该方法相对标准偏差小于10%,检测线(S/N=3)为1mg/l,平均回收率94.3%~101.1%,分析速度快、稳定性好、效率高、结果准确。经过试验该方法完全能满足丙烯中CO、CO2及烃类杂质的分析。
丙烯中CO/CO2测TDX-01填充柱 测试谱图:



Hydride CO/CO2 measurement TDX-01 packed column
Hydride CO/CO2 measurement TDX-01 packed column Details:
Statio
Specification: 2m*3mm
Particle size: 60-80 mesh
Model: TDX-01
Material: Stainless steel
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd., gas chromatograph equipped with two hydrogen flame detectors, a methane reformer to simultaneously determine the CO, CO2 and hydrocarbon impurities in propylene, established a simple, accurate and fast Analytical method for the determination of trace impurities in propylene. The relative standard deviation of the method is less than 10%, the detection line (S/N=3) is 1mg/l, and the average recovery rate is 94.3%~101.1%. The analysis speed is fast, the stability is good, the efficiency is high, and the result is accurate and reliable. After testing, the method can fully meet the analysis of CO, CO2 and hydrocarbon impurities in propylene.
相关产品
在线留言 |