15562228838(微信同号)13963221227(微信同号)
HH-624 1,2-二氯乙烷及其降解产物GC-MS测定
您所在的位置:首页 > 产品展示

HH-624 1,2-二氯乙烷及其降解产物GC-MS测定

如果你感兴趣的话,可以电话:0632-5667636

产品名称:HH-624 1,2-二氯乙烷及其降解产物GC-MS测定

产品型号:HH-624

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

1,2-二氯乙烷及其降解产物GC-MS测定,氯乙酸,氯乙醇,顶空,液化石油气,二甲醚,甲醛,甲酸,甲醇,变压器油溶解气,六氟化硫,硫化物,羰基硫,植物油,脂肪酸,芝麻香白酒,3-甲硫基丙醇

HH-624 1,2-二氯乙烷及其降解产物GC-MS测定的详细介绍

1,2-二氯乙烷及其降解产物GC-MS测定
1,2-二氯乙烷及其降解产物GC-MS测定 详细信息:

填料:6% 氰丙基苯基/94% 二甲基聚硅氧烷
性:弱性到中等性固定相
相当于 USP 固定相 G43

型号:HH-624

规格:30m*0.32mm*1.8um

滕州市浩瀚色谱仪器技术服务有限公司,建立了气相色谱-质谱联用法(GC-MS)测定纺织品中1,2-二氯乙烷及其降解产物的方法。样品经甲醇超声提取后,降解物2-氯乙醇可直接用气质联用仪测定,氯乙酸经衍生为氯乙酸甲酯后,用气质联用仪测定,外标法定量。结果表明:在0.05~30 mg/L范围内,1,2-二氯乙烷、2-氯乙醇、氯乙酸的线性相关系数分别为0.999 6、0.999 0、0.999 0,在较宽的质量浓度范围内有很好的线性关系;方法的检测低限均为0.5 mg/kg。7种阴性纺织品,在0.5、1.0和5.0 mg/kg 3个加标水平下,1,2-二氯乙烷、2-氯乙醇、氯乙酸的平均回收率范围为85.0%~101.6%,相对标准偏差为3.7%~7.9%。该方法简便、准确、灵敏度和度高,适用于纺织品中1,2-二氯乙烷及其降解产物的分析检测。

1,2-二氯乙烷及其降解产物GC-MS测定 图片:



Determination of 1,2-dichloroethane and its degradation products by GC-MS
1,2-Dichloroethane and its degradation products GC-MS determination Details:

Filler: 6% cyanopropyl phenyl / 94% dimethyl polysiloxane
Polarity: weak polarity to medium polarity stationary phase
Equivalent to USP stationary phase G43
Model: HH-624

Specification: 30m*0.32mm*1.8um

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. established a method for the determination of 1,2-dichloroethane and its degradation products in textiles by gas chromatography-mass spectrometry (GC-MS). After the sample was ultrasonically extracted by methanol, the degraded product 2-chloroethanol can be directly measured by a gas chromatography-mass spectrometer. After the chloroacetic acid is derivatized into methyl chloroacetate, it is determined by a gas chromatography-mass spectrometer and quantified by an external standard method. The results showed that the linear correlation coefficients of 1,2-dichloroethane, 2-chloroethanol and chloroacetic acid were 0.999 6, 0.999 0 and 0.999 0 in the range of 0.05~30 mg/L, respectively. There is a good linear relationship in the range; the detection limit of the method is 0.5 mg/kg. In 7 negative textiles, the average recoveries of 1,2-dichloroethane, 2-chloroethanol and chloroacetic acid ranged from 85.0% to 101.6% at 0.5, 1.0 and 5.0 mg/kg. The standard deviation is 3.7% to 7.9%. The method is simple, accurate, sensitive and precise, and is suitable for the analysis and detection of 1,2-dichloroethane and its degradation products in textiles.

Determination of 1,2-dichloroethane and its degradation products by GC-MS

相关产品

HH-PLOT Q 苯乙烯-二乙烯基苯多孔聚合物毛细管柱测试水分
苯乙烯-二乙烯基苯多孔聚合物毛细管柱测试水分,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,三甲胺,乙胺
HH-THC-10 境空气中非甲烷总烃测定脱活毛细管柱
境空气中非甲烷总烃测定脱活毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油,多氯联苯,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,三甲胺,乙胺
1M*1/8,, MS-5Å甲烷柱应用天瑞测定环境空气中CH4
MS-5Å甲烷柱应用天瑞测定环境空气中CH4,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
GDX-101,, 化工产品水分测定填充柱应用安捷伦7890
化工产品水分测定填充柱应用安捷伦7890,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,消毒剂,氨水,氨气,乙酸乙酯,医疗器械
2M*4MM,, 客户定制的13X分子筛填充柱
客户定制的13X分子筛填充柱,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,消毒剂,氨水,氨气,乙酸乙酯,医疗器械
1.6M*3MM,, 树脂键合相–聚乙二醇丁二酸玻璃柱测定乙醇胺
树脂键合相–聚乙二醇丁二酸玻璃柱测定乙醇胺应用PE580,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,消毒剂,氨水,氨气,乙酸乙酯,医疗器械

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 2*0等于多少?答案:0
 
仪器交易网
8
推荐收藏该企业网站