15562228838(微信同号)13963221227(微信同号)
GDX-502填充柱 测定固定污染源废气中非甲烷总烃
您所在的位置:首页 > 产品展示 > 填充柱

GDX-502填充柱 测定固定污染源废气中非甲烷总烃

如果你感兴趣的话,可以电话:0632-5667636

产品名称:GDX-502填充柱 测定固定污染源废气中非甲烷总烃

产品型号:GDX-502填充柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

测定固定污染源废气中非甲烷总烃,液化石油气,二甲醚,甲醇,甲酸,变压器油,溶解气,三甲胺,环氧乙烷,芝麻香白酒,3-甲硫基丙醇,植物油,脂肪酸,6号溶剂残留,口罩,氨水

GDX-502填充柱 测定固定污染源废气中非甲烷总烃的详细介绍

测定固定污染源废气中非甲烷总烃
测定固定污染源废气中非甲烷总烃 详细信息:

固定相:高分子小球

GDX-502,2m*3mm,2m*4mm,2m*1/8,60-80目

甲烷柱


总烃柱

2m*3mm,2m*4mm,2m*1/8,硅烷化玻璃微球

滕州市浩瀚色谱仪器技术服务有限公司,以HJ/T 38-1999为基础,针对气相色谱法测定污染源废气中非甲烷总烃存在的诸多问题进行探讨,在总烃出峰峰形、废气氧峰值测定、高沸点物质干扰等方面做了研究试验。结果表明,1ml定量环容易造成总烃出现平头峰,改成0.25ml定量环能得到好的峰形;非甲烷总烃的检出限为0.04 mg/m~3(以碳计);氧峰值与氧量具有线性关系,应根据氧量判断氧峰值大小,而不是统一扣除除烃空气氧峰值;废气中存在高沸点组分时,容易吸附于采样容器内壁,将样品加热100℃再测试可提高该组分的检出率。

测定固定污染源废气中非甲烷总烃 图片:



Determination of non-methane total hydrocarbons in fixed source waste gas
Determination of non-methane total hydrocarbons in fixed source waste gas Details:

Stationary phase: polymer pellet
GDX-502, 2m*3mm, 2m*4mm, 2m*1/8, 60-80 mesh
Methane column

Total hydrocarbon column
2m*3mm, 2m*4mm, 2m*1/8, silanized glass microspheres

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd., based on HJ/T 38-1999, discusses the problems of gas chromatography in the determination of non-methane total hydrocarbons in waste gas from pollution sources. Research and tests have been carried out on the determination and interference of high-boiling substances. The results show that the 1ml loop is likely to cause a flat peak in the total hydrocarbons, and a good peak shape can be obtained by changing to a 0.25 ml loop; the detection limit of non-methane total hydrocarbons is 0.04 mg/m~3 (calculated as carbon); It has a linear relationship with the oxygen content. The oxygen peak value should be judged according to the oxygen amount, instead of uniformly deducting the peak of the oxygen removal air. When there is a high boiling component in the exhaust gas, it is easy to adsorb to the inner wall of the sampling container, and the sample is heated to 100 ° C and then tested. The detection rate of the component can be increased.

Determination of non-methane total hydrocarbons in fixed source waste gas

相关产品

30m*0.53mm*1.0um,, OV-101毛细管柱应用在岛津GC-2030上
OV-101毛细管柱应用在岛津GC-2030上,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
3m*3mm,, 20%PEG-400/6201填充柱应用赛默飞1300
20%PEG-400/6201填充柱应用赛默飞1300,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
HH-BYD,, 1,4丁炔二醇的测定填充柱应用安捷伦7890B
1,4丁炔二醇的测定填充柱应用安捷伦7890B,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
6201,, 纯氖中总碳测定的填充柱应用岛津GC2010
纯氖中总碳测定的填充柱应用岛津GC2010,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
TDX-01,, 纯氖中氦/氢测定6m*4mm的填充柱
纯氖中氦/氢测定6m*4mm的填充柱,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
岛津3m*4Mm,, 5Å分子筛填充柱测定纯氖中氧+氩+氮
5Å分子筛填充柱测定纯氖中氧+氩+氮,岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸