15562228838(微信同号)13963221227(微信同号)
Tenax-TA 吸附管测定室内TVOC污染物
您所在的位置:首页 > 产品展示 > 专用填充柱

Tenax-TA 吸附管测定室内TVOC污染物

如果你感兴趣的话,可以电话:0632-5667636

产品名称:Tenax-TA 吸附管测定室内TVOC污染物

产品型号:Tenax-TA

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

Tenax-TA吸附管测定室内TVOC污染物,热解吸仪,裂解进样器,多氯联苯,植物油,6号溶剂残留,环氧乙烷,三甲胺,二甲醚,甲醇,甲酸,乙酸乙酯,甲醛,非甲烷总烃

Tenax-TA 吸附管测定室内TVOC污染物的详细介绍

Tenax-TA吸附管测定室内TVOC污染物
Tenax-TA吸附管测定室内TVOC污染物 详细信息:

固定相:Tenax-TA

粒度:60-80目

规格:1/4*3.5英寸,6*150mm,6*90,填料200mg,其他规格可定制

材质:玻璃,不锈钢

应用:GB_50325-2010_民用建筑工程室内环境污染控制规范

滕州市浩瀚色谱仪器技术服务有限公司,研究了影响气相色谱法测定室内空气中TVOC(总挥发性有机化合物)浓度的主要因素。采样过程中如流量达不到0 . 5L min ,可通过延长采样时间使终采样体积达到10L ;采样前延长通风时间使室内外空气充分对流,有利于室内残留污染物质的扩散,能反映重新封闭后有机挥发物1h时段内释放的实际浓度。TVOC各组分的热解吸率与该组分的分子量和性有关;热解吸率随解吸时间的延长而降低,操作中以1~3min比较合适。将初始柱温从5 0℃提高到70℃,不设停留时间,终止温度从2 5 0℃降为2 30℃,可以将样品分析时间由5 5min缩短到32min而对分析结果几乎没有影响。


Tenax-TA吸附管测定室内TVOC污染物 图片:




Determination of indoor TVOC pollutants by Tenax-TA adsorption tube
Tenax-TA adsorption tube for measuring indoor TVOC pollutants

Stationary Phase: Tenax-TA
Particle size: 60-80 mesh
Specifications: 1/4*3.5 inches, 6*150mm, 6*90, packing 200mg, other specifications can be customized
Material: glass, stainless steel
Application: GB_50325-2010_Code for indoor environmental pollution control of civil construction projects

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. studied the main factors affecting the determination of TVOC (total volatile organic compounds) in indoor air by gas chromatography. If the flow rate does not reach 0. 5L min during the sampling process, the final sampling volume can reach 10L by extending the sampling time. The ventilation time is extended before sampling to make the indoor and outdoor air convect fully, which is beneficial to the diffusion of residual pollutants in the room and can reflect the re-enclosure. The actual concentration of post-organic volatiles released during the 1 h period. The thermal desorption rate of each component of TVOC is related to the molecular weight and polarity of the component; the thermal desorption rate decreases with the extension of the desorption time, and it is suitable for 1 to 3 minutes in the operation. Increasing the initial column temperature from 50 °C to 70 °C without stopping time, the termination temperature was reduced from 250 °C to 2 30 °C, and the sample analysis time was shortened from 55 min to 32 min with little effect on the analytical results.


Determination of Indoor TVOC Contaminants by Tenax-TA Adsorption Tube

相关产品

1/8*4m,, Hayesep S填充柱配安捷伦8890岛津赛默飞
Hayesep S填充柱配安捷伦8890岛津赛默飞,液化石油气,顶空进样器,粗苯,三苯,Hayesep A填充柱在赛默飞安捷伦8890岛津醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
3m*1/8, Porapak QS填充柱在赛默飞安捷伦岛津赛默飞应用
Porapak QS填充柱在赛默飞安捷伦岛津赛默飞应用,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
1/8*4m,60-80目,, 408有机担体填充柱安装在安捷伦8890上
408有机担体填充柱安装在安捷伦8890上,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
1/8*4m,60-80目,, 403有机担体安装在安捷伦8890上
403有机担体安装在安捷伦8890上,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
HH-NH3-C2H2 乙炔氨装置在线分析专用填充柱应用安捷伦岛津
乙炔氨装置在线分析专用填充柱应用安捷伦岛津,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲醚,植物油,药典,二氧化碳,甲醛,甲酸,乙酸
20% PEG-20M / GCS880 AW DMCS,, HJ/T 35-1999 固定污染源
HJ/T 35-1999 固定污染源排气中乙醛的测定 填充柱,便携式甲烷转化炉,一氧化碳,甲烷,二氧化碳,高纯气体,H2,O2,N2,Ar,CO,CO2,CH4

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 7+8等于多少?答案:15
 
仪器交易网
8
推荐收藏该企业网站