15562228838(微信同号)13963221227(微信同号)
GDX-502 气相色谱法测定非甲烷总烃的研究
您所在的位置:首页 > 产品展示

GDX-502 气相色谱法测定非甲烷总烃的研究

如果你感兴趣的话,可以电话:0632-5667636

产品名称:GDX-502 气相色谱法测定非甲烷总烃的研究

产品型号:GDX-502

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

气相色谱法测定非甲烷总烃的研究,液化石油气,顶空进样器,药典,二氧化碳,乙酸乙酯,环氧乙烷,三甲胺,粗苯

GDX-502 气相色谱法测定非甲烷总烃的研究的详细介绍

气相色谱法测定非甲烷总烃的研究
气相色谱法测定非甲烷总烃的研究 详细信息:

滕州市浩瀚色谱仪器技术服务有限公司,用玻璃注射器(气袋)采集气体样品,以双柱单氢火焰离子化检测器的气相色谱仪直接进行测定.进样1.0mL样品分别进入汽化室的总烃柱甲烷柱中,由于这两个柱子填充材料和长短差异,总烃先在FID上产生响应,然后甲烷在FID上产生响应.总烃的浓度扣除甲烷浓度和除烃空气氧的浓度值,即可得到非甲烷总烃(NMHC)的浓度,可以实现单次进样,同时完成总烃、甲烷、非甲烷总烃浓度的测定.文章研究1.37~22.3 mg/m3浓度甲烷标准气,得出甲烷标准曲线方程为Y =715X +829,r=0.9990,相对标准偏差为0.26%~1.8%,总烃标准曲线方程Y=695X+ 724,相对标准偏差为0.35% ~ 1.4%,除烃空气(O2-N2,20.8%)相对标准偏差为0.75%.该法用于环境空气和固定污染源有组织排放中NMHC含量分析,操作简单,实验结果满意.

提供完整的分析方案
解决O2的干扰,负值的问题,

气相色谱法测定非甲烷总烃的研究 图片:

GDX-104/502,硅烷化玻璃微球填充柱
30m*0.53mm毛细管柱

Determination of Non-methane Total Hydrocarbons by Gas Chromatography
Determination of non-methane total hydrocarbons by gas chromatography

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. collects gas samples with glass syringes (air bags) and directly measures them with a gas chromatograph of a two-column single hydrogen flame ionization detector. The total volume of 1.0 mL samples entering the vaporization chamber In the hydrocarbon column and the methane column, due to the difference in the material and length of the two columns, the total hydrocarbon first responds on the FID, and then the methane responds on the FID. The total hydrocarbon concentration minus the methane concentration and the concentration of the dehydrogenated air oxygen The concentration of non-methane total hydrocarbons (NMHC) can be obtained, and a single injection can be achieved, and the total hydrocarbon, methane, and non-methane total hydrocarbon concentration can be determined. The article studies 1.37-22.3 mg/m3 concentration of methane standard gas. The methane standard curve equation is Y = 715X + 829, r = 0.9990, the relative standard deviation is 0.26% to 1.8%, the total hydrocarbon standard curve equation Y = 695X + 724, the relative standard deviation is 0.35% ~ 1.4%, except for hydrocarbon air ( O2-N2, 20.8%) The relative standard deviation is 0.75%. This method is applied to the analysis of NMHC content in organized emissions of ambient air and fixed pollution sources. The operation is simple and the experimental results are satisfactory.

Provide a complete analysis solution
Solve the interference of O2, the problem of negative value, the choice of column, and develop a unique analytical method

Determination of Non-methane Total Hydrocarbons by Gas Chromatography

GDX-104/502, silanized glass microsphere packed column
30m*0.53mm capillary column

相关产品

KCL/AL2O3,, 氯化钾去活的三氧化二铝填充柱应用赛默飞1300
氯化钾去活的三氧化二铝填充柱应用赛默飞1300,液化石油气,二甲醚,甲缩醛,乙缩醛,粗苯,三苯,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,三甲胺,乙胺,医疗器械,环氧乙烷
80-100目,, Porapak N色谱填料应用安捷伦岛津赛默飞
Porapak N色谱填料应用安捷伦岛津赛默飞,液化石油气,二甲醚,甲缩醛,乙缩醛,粗苯,三苯,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,三甲胺,乙胺,医疗器械,环氧乙烷
13X填充柱/氧化锆,, 惰性气体中微量氢、氧、甲烷、一氧化
惰性气体中微量氢、氧、甲烷、一氧化碳含量的测定,液化石油气,二甲醚,甲缩醛,乙缩醛,粗苯,三苯,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,三甲胺,乙胺,医疗器械,环氧乙烷
HH-C2-30,, 乙烯乙烷乙炔的测定毛细管柱应用岛津2014
乙烯乙烷乙炔的测定毛细管柱应用岛津2014,室内空气,焦炉煤气,炼厂气,天然气,三甲胺,芝麻香白酒,3-甲硫基丙醇,乙酸乙酯,医疗器械,环氧乙烷,三甲胺,二甲醚,粗苯,水分,噻吩,氨
HH-790CH4-GC,, 便携式甲烷转化炉顶空法测定海水中一氧化
便携式甲烷转化炉顶空法测定海水中一氧化碳,一氧化碳,甲烷,二氧化碳,高纯气体,H2,O2,N2,Ar,CO,CO2,CH4
CarbonxenTM1006-PLOT,, 进出口水产品中一氧化碳残留量的
进出口水产品中一氧化碳残留量的检验毛细管柱,室内空气,焦炉煤气,炼厂气,天然气,三甲胺,芝麻香白酒,3-甲硫基丙醇,乙酸乙酯,医疗器械,环氧乙烷,三甲胺,二甲醚,粗苯,水分,噻吩,氨

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 3-7等于多少?答案:-4
 
仪器交易网
8
推荐收藏该企业网站